Irreversible paints

TMC Clearline Thermal Indicating paints provide a simple method of measuring temperature with a single paint pack. Providing a non reversible, accurate method of measuring temperature throughout the range of 104°C/219°F to 1270°C/2318°F.

MAIN ADVANTAGES OF THESE IRREVERSIBLE PAINTS

  • No primer necessary for most surfaces
  • Fast reaction time
  • Superior performance in normal and hostile environments
  • Ideal for producing thermal surveys
  • A strong and clear colour contrast
  • Resistant to oil, steam and water
  • Requires no additives

43 standard change points available for temperatures 104°C/219°F to 1270°C/2318°F

SINGLE CHANGE PAINTS

Single Change Thermal Paints are now colour fast in direct sunlight, resistant to chemical abuse and provide a clearline colour change, proving to be an extremely useful aid to the industrial, chemical and petrochemical markets.

An ideal tool for monitoring lined vessel plant, detecting rise in surface temperature where the refractory linings have broken down, acting as an invaluable tool for this type of industry.

Supplied in 250ml, 500ml, 1 litre & 2.5 litres.

MULTI CHANGE PAINTS

Multi Change Thermal Paints withstand hostile environments and prove a valuable asset, particularly when used in conjunction with gas turbines and jet engines. Being the only paint of its type known to retain its surface adhesion at these temperatures thus offering a high degree of protection from erosion. Used extensively in rocketry and high speed flight technology, these paints prove to be an invaluable tool in thermal measurement.

Supplied in 250ml, 500ml, 1 litre & 2.5 litres.

SINGLE CHANGE PAINTS

Specification: Ref. SC paint;

Accuracy: +/- 5%.

Range: 135°C/275°F to 630°C/1166°F

Note: Single change paints are also available at 48oC and 80oC. However, they are Quasi-reversible. They revert back to their original colour when water is applied.

MULTI CHANGE PAINTS

Specification: Ref MC paint;

Accuracy: +/- 5%

Range: 104°C/219°F to 1270°C/2318°F

RACING KIT

It's ideal to carry out tests at the motor components during competition.

RACING KIT

Contents:

  • 3 x 15ml Jars of assorted paints
  • 1 x 15ml jar of solvent
  • 3 x brush for application

TECHNICAL INFORMATION

Some paints are available in a Polyurethane type finish.

All Thermal Paints are time/temperature dependent and in being so, such paints have a trigger temperature below their specified rating.

A 235°C/455°F Thermal Indicating paint after 1 hour would require only a sustained temperature of 218°C/424°F to change its colour, however, a temperature of 180°C/356°F will not cause a colour change of the paint, therefore such a paint could be recommended for work on projects which do not exceed the normal running conditions of 180°C/356°F. Being a general guide only, specific details should always be requested. To obtain further advice we will need the following information:

  • (a) The type of surface to be painted, i.e. metal, stone, etc.
  • (b) Required trigger temperature
  • (c) The surface temperature under normal conditions
  • (d) The ambient temperature

CAUTION: It is, when testing, advisable to apply two coats of thermal paint. No undercoat is necessary when used for test purposes. When calculating requirements allow 1 litre per 6 sq. metres.

 

Temperature control with Crayons

Crayons are an alternative way to control temperature when there is a lack of space, or when temperatures rise above 290ºC where strips can't be used.

Test example of change

Temperature control with Crayons

Colour Change Crayon Behaviour

When applied to pre-heated surfaces, if colour change takes place:

(a) within 1-2 seconds, the temperature is within +/- 5ºC of its rating

(b) instantly, the temperature is higher than its rating

(c) after two seconds, the temperature is lower than its rating

Accuracy: +/-5ºC

 

REF INITIAL COLOUR COLOUR CHANGES AS BELLOW
120   120ºC/248ºF    
245   245ºC/473ºF 335ºC/635ºF 505ºC/941ºF
600   600ºC/1112ºF    

 

Temperature monitoring in the textile industry

Temperature measuring devices specially designed for their use in textile industries. This temperature control prevents the over-heating which could afterwards cause broken fibers, and also alerts when heating is weak giving place to a fragile union between cloths.

Standard Strips:

Range 1: 104-143 Range 4: 121-160
110-116-121-127-132-138-143 ºC 121-127-132-138-143-149-154-160 ºC
Range 2: 143-182 Range 5: 160-199
149-154-160-166-171-177-182 ºC 160-166-171-177-182-188-193-199 ºC
Range 3: 182-224  
188-193-199-204-210-216-224 ºC  

 

 

 

 

 

 

 

 

Other ranges available, when asked for, for example:

210-260
210-216-224-232-241-249-254-260 ºC

Irreversible TDI Temperature sensor labels HACCP

The TDI irreversible temperature indicator labels are designed to withstand the extreme conditions within an Industrial Dishwasher, allowing equipment cleanliness standards to be monitored during disinfection processes. The TDI asures that the selected temperature in the dishwasher has been achieved, that is indicated with a permanent change in colour. Dishwashers used for catering services usually work within 60 to 66º C, but nowadays, the minimum temperature should be 71ºC which is the reference temperature where the materials are considered to be disinfected.

This thermometer has been specifically designed to withstand the conditions undergone in the washing cycle, including the resistance to the agressive chemical substances applied. All of that without losing its capacity to monitor the temperature correctly. Hobart, known dishwasher manufacturer, collaborated when creating this device. Its final design has a size inferior to the one of a stamp. TDI's secret to succeed is the adhesive material used, which not only stands the whole washing cycle but then is easy to remove by us to attach to the HACCP (Hazard Analysis and Critical Control Point) report.

 

Ref.TDI01, After (Black) / Before (white)

Thanks to its reliability and easy functioning, TDI guarantees higene responsibles that they are using disinfected dishes.

Ref.TDI01, After (Black) / Before (white)

 

Ref.  Available Tª
TDI03/02C 65-71-82ºC

 

It can also be produced for any other temperature detection untill 99ºC. For further information don't doubt to contact us.

Supply: Min. 1000 units
Delivery: 3-4 weeks

Micro temperature indicators

Micro-Indicators are temperature sensitive strips with a reduced size which makes them specially useful to record increases in temperature in electronic devices such as condensers, resistances, transistors and many others, to prevent malfunctions. These thermometers are very easy to use: You just have to stick them on the device. When the critical temperature is reached the strip turns black revealing a posible malfunction. As these strips rest on the surface to be monitored they give a precise reading of the exact temperature the device undergoes. Furthermore the strips can be attached to a document as part of a quality control record if required. There are three main types of Micro Indicator which are selected depending on the kind of temperature control required:

Clock Indicator
Size: 14 mm Diameter, Type: Round, adhesive, Scale: ºC or ºF, Supply: 10 unit packs

Type 1 Clock Indicator.
Type 1 Clock Indicator.

 

1 40-43-46-49-54ºC
2 60-65-71-77-82ºC
3 88-93-99-104-110ºC
4 116-121-127-132-138ºC
5 143-149-154-160-166ºC
6 171-177-182-188-193ºC
7 199-204-210-216-224ºC
8 232-241-249-254-260ºC

 

4 Level Micro Strip
Size: 4 x 11 mm Type: Horizontal, Scale: ºC o ºF Supply: 10 unit packs

Type 1 Micro Strip

Type 1 Micro Strip

 

1 40-42-44-46ºC
2 49-54-60-65ºC
3 71-77-82-88ºC
4 93-99-104-110ºC
5 116-121-127-132ºC
6 138-143-149-154ºC
7 160-166-171-177ºC
8 182-188-193-199ºC
9 204-210-216-224ºC

 

Encapsulated Indicator
Size: 12 x 13 mm Type: Max. temperature spot Scale: ºC / ºF Supply: 50 unit packs

 Encapsulated 88ºC
Encapsulated 88ºC